airmoVOC C10-C40

Technical Specifications

airmoVOC C6-C20+ - Volatile and Semi Volatile Hydrocarbons analyzer
  • Analysis Range:
    • From C10 (Hexane, Dimethylbutane) to C40 (Benzo(a)pyrene and N-Eicosane)
  • Detection Limit:
    • Benzene: 5 ppt or 0.0164 µg/m³
    • Naphthalene: 10 ppt or 0.05 µg/m³
  • Detection Range:
    • Benzene: 0.1 to 380 µg/m³
    • Naphthalene: 0.05 to 400 µg/m³
  • Relative Standard Deviation (Repeatability):
    • < 0.3% over 48h (RT)
    • < 3% over 48h (Concentration)
  • Cycle Time:
    • 30 to 60 minutes (depending on application)
    • 90 to 120 minutes (optional)
  • Gas Supply:
    • H2 (FID and carrier gas): 45 mL/min (inlet 4 bars; 1/16’’ double ferrule)
    • Air (FID): 450 mL/min (inlet 4 bars; 1/8’’ double ferrule)
    • Sample inlet: 1/4’’ vacuum pump
    • Pneumatic valve 90ml/commutation
  • Sample Volume:
    • Up to 2200 mL (programmable)
  • Power Supply:
    • Main: 230 V / 115 V, 50 Hz / 60 Hz
    • Battery: 24 V (optional)
  • Electrical Consumption:
    • Mean: 300 VA, Peak: 460 VA
  • Dimensions and Weight:
    • Rack: 19’’ (5U)
    • Height: 222 mm
    • Width: 482 mm
    • Depth: 600 mm
    • Net Weight: 22 kg

Analysis for light S VOCs and heavy S VOCs from C10 to C40

The airmoVOC C10-C40 is a gas chromatograph specifically designed for the analysis and monitoring of trace and ultra-trace levels of light and heavy S VOCs from C10 to C40, such as linear alkanes and gaseous PAHs. This system is equipped with a flame ionization detector (FID) for precise analysis and integrates all components into a compact 19’’ rack.

Key Features:

  • Wide Analysis Range:
    • Detects linear alkanes up to N-Eicosane (C40) and gaseous PAHs from Naphthalene to Benzo(a)pyrene (C20).
    • Covers applications from urban air monitoring to industrial process emissions and VOC analysis in water.
  • Advanced Sampling Technology:
    • Features uninterrupted sampling with pre-concentration on an absorbent tube.
    • Utilizes thermo-desorption and programmable temperature gradient up to 350°C for precise compound detection.
  • High Sensitivity and Reliability:
    • Detection down to 5 ppt for Benzene and 10 ppt for Naphthalene.
    • Stable and accurate results with < 0.3% RSD for retention time over 48 hours.
  • Software Control with VISTACHROM®:
    • Allows remote monitoring, full traceability, and setup of threshold alarms.
    • Supports data export via MODBUS, 4-20mA, or 0-10V outputs.

Applications:

  • Urban and non-urban area pollution control
  • Indoor and outdoor BTEX monitoring
  • Plant and process emissions
  • Contaminants extracted from plastics, PET, and oils
  • VOC analysis in water (using a purge module)

Ordering Information:

  • Model: A10000

Tests reports & Certifications